ºÚÁϲ»´òìÈ can evaluate the Degree of Sensitization (DoS) on-site using a non-destructive Double Loop Electrochemical Potentiokinetic Reactivation (DL-EPR) test method, to provide you with faster and more effective test results. 

Sensitization in austenitic stainless steels causes the susceptibility of materials to Intergranular Corrosion (IGC) and Polythionic Acid Stress Corrosion Cracking (PASCC), which are well-known phenomena in the chemical and petrochemical industries.

There are several methods for determining whether the material is sensitized, such as ASTM A262 practice E, however these methods are destructive and cannot be carried out in the field.

As part of our on-site metallographic testing and analysis, ºÚÁϲ»´òìÈ can perform a non-destructive DL-ERP testing of austenitic alloys on-site to determine the degree of sensitization and deliver much easier and faster results than laboratory tests.

 

Double Loop Electrochemical Potentiokinetic Reactivation (DL-EPR) test method

Our Engaged Experts carry out the test on-site by attaching a test tube to the prepared surface. We can run a polarization scan from 100 mV below OCP (~ -500mV) to approx. 500mV and immediately reversed. From this cyclic scan we can determine the maximum current density for the activation cycle (Iac) and the reactivation cycle (Ireac).

 

DoS value and grain size 

The DOS-value is the ratio of Ireac/Iac. As grain size can have a huge influence on the DoS measurements, results obtained directly from the DOS test have to be corrected for grain size. ºÚÁϲ»´òìÈ will carry out a replica examination testing from the examined surface to determine the grain size and provide qualitative results regarding the amount, distribution and nature of precipitation. The combination of DoS testing with Replica testing will give a quantitative and qualitative assessment of the material condition.

 

Limitations of on-site DL-PR and DoS 

The DOS-value produced is a relative term (%) and not the absolute current densities. Equipped with state-of-the-art laboratories and the latest testing equipment, ºÚÁϲ»´òìÈ’s Engaged Experts offer effective approaches to perform DL-EPR and measure DoS more accurately when conducted on-site.  

We are aware of the edge-effects that are likely to occur during testing, and our experts ensure that these effects and inaccuracies are canceled out. We complement our on-site capabilities with additional laboratory tests where necessary and we have been actively developing acceptance criteria for on-site measurements. 

For more information about how we perform on-site EPR measurements - DoS testing, or to request a quote, contact us today

White Paper: What is Metallurgical Testing? 

Metallurgical testing covers a huge scope of industries. Could metallurgical testing be helpful for you? Dr. John Tartaglia helps guide you through the basics of metallurgical testing.

Read MORE

Replication Metallography: A Non-Destructive Solution 

ºÚÁϲ»´òìÈ discusses replication metallography as a non-destruction solution to metallurgical evaluation.

Read MORE

Webinar: Corrosion of Stainless Steel

This webinar shows examples of corrosion damage and guides you through how to avoid corrosion in your stainless steel products to prevent product failure and costly repairs.

Watch Now

Our team of over 9,000 Engaged Experts in North America, Europe, The Middle East, Australia, Asia and Africa are ready to help you.